Back to: Home > Our Products > PS2 Single > TC-PA > TC-460PA
 
   TC-460PA
Model : TC-460PA Power : 460W
> AC Input:

- VOLTAGE: 100~240V, (Active PFC)
- FREQUENCY: 47~63Hz
- INPUT CURRENT: 8A
- INRUSH CURRENT: 65A/125A MAX FOR 115/230

   DC Output
OUTPUT
VOLTAGE
OUTPUT CURRENT
REGULATION
OUTPUT
MIN(A)
MAX(A)
LOAD
LINE
RIPPLE & NOISE
MAX.[P-P]
+5V
3
30
±5%
±1%
50mV
+12V1
1
14
±5%
±1%
120mV
+12V2
1
14
±5%
±1%
120mV
-5V
0.1
0.8
±10%
±1%
150mV
-12V
0.1
1
±10%
±1%
150mV
+3.3V
1
30
±5%
±1%
50mV
+5VSB
0.1
2
±5%
±1%
50mV
  The combined output power +5V&+3.3V shall not exceed 30A.
The combined output power +5V & +12V & +3.3V maximum output 440W.
The total power shall not exceed 460W.

   Features
 
> TEMPERATURE RANGE: Operation 0℃~50℃
> HOLD UP TIME: 16ms at maximum load&normal input voltage
> EFFICIENCY: 68% TYPICAL(Normal Line)
> ATX 12V / EPS 12V
> POWER GOOD SIGNAL: Should be asserted high to indicate that+5VDC and +3.3VDC
   output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms.
> OVER POWER PROTECTION: The power supply shall shout down output power exceeds 130% to 160%
> OVER VOLTAGE PROTECTION: Standard on +5.0V, set at 6.25VDC ± 0.75VDC
> SHORT CIRCUIT PROTECTION: A short circuit placed between the DC return and
   the output shall cause no damage and the power supply shall shutdown.
> EMI: FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B.
> Meet EN-61000-3-2 CLASS D ( Active PFC )
> AGENCY APPROVALS: UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950)
> REMOTE ON/OFF CONTROL: When PS-ON is pulled to TTL Low, the DC output
   is to be enabled, When PS-OFF is pulled to TTL high, the DC output is to disabled.
> COOLING: By forced air 1x80mm Fan
> DIMENSION: D140 X W150 X H86mm


   Download
 
> Specification:

> Drawing:

   Connectors

20+4 Pin
P4 MB
Peripheral
FDD
8-Pin
SATA
X 1
X 1
X 6
X 1
X 1
X 2