Model : TC-300R2U-H Power : 300W
> AC Input:
- VOLTAGE: 90~264VAC Full Range
- FREQUENCY: 50/60Hz.
- INPUT CURRENT: 8A for 115V AC, 4A for 230VAC.
- INRUSH CURRENT: 60A for 115VAC, 80A for 230VAC
 |
|
|
|
|
|
|
| Output Voltage |
+5V DC |
+12V DC |
-5V DC |
-12V DC |
+3.3V DC |
+5VSB |
| Output Current(Max) |
25A |
16A |
0.5A |
0.8A |
25A |
2A |
| Output Current(Min.) |
3A |
2A |
0.1A |
0.1A |
0.3A |
0.1A |
| Ripple/Noise Max.(P-P): |
50mv |
120mv |
150mv |
150mv |
50mv |
50mV |
| Line Regulation: |
±1﹪ |
±1﹪ |
±1﹪ |
±1﹪ |
±1﹪ |
±1﹪ |
| Load Regulation: |
±5﹪ |
±5﹪ |
±10﹪ |
±10﹪ |
±5﹪ |
±5﹪ |
|
|
> DIMENSION:D280 X W170 X H42mm / D11 x W6.69 x H1.65 (inches)
> COOLING:By forced air
> TEMPERATURE RANGE:Operation 0˚C~50˚C
> HOLD UP TIME:16ms at maximum load & normal input voltage
> EFFICIENCY:≧73﹪at full load. (Normal Line)
> ATX 12V / EPS 12V
> POWER OK:PW-OK is power good signal and should be asserted high by the power supply to indicate that +5VDC and +3.3VDC output are above the under voltage thresholds of the power supply TTL. compatible signal out with 100ms to 500ms.
> OVER POWER PROTECTION: The power supply shall shut down when output power exceeds 130﹪to 160﹪ of full load and require a power on cycle be performed by the operate
> OVER VOLTAGE PROTECTION: Standard on +5.0V output, set at 6.25VDC ± 0.75VDC.
> SHORT CIRCUIT PROTECTION: A short circuit placed between the DC Return and the output shall cause No damage and the power supply shall shutdown.
> EMI/RFI: FCC part 15, Subpart B, Class B, EN55022 CISPR22 Class B, EN61000-3-2 (ACTIVE PFC), EN61000-4-2, -3, -4, -5, -6, -8, -11
> AGENCY APPROVALS: UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950), CB Certification
> MTBF OF POWER SUPPLY ELECTRONNIS: 100,000 hours at full load and 25℃ ambient temperature
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
| 24 Pin |
P4 MB |
Peripheral |
FDD |
8-Pin |
SATA |
| X 1 |
X 1 |
X 9 |
X 1 |
X 1 |
X2 |
|
|
|
|
|
|
|
|