> DIMENSION: L200 x W150 x H 86 mm
> COOLING: By forced air
> OPERATION TEMPERATURE: 0℃ to 50℃
> HOLD UP TIME: 16ms at maximum load & normal input voltage
> EFFICIENCY: ≧ 73﹪at full load. (Normal Line)
> ATX 12V / EPS 12V
> POWER-OK: PW-OK is power good signal and should be asserted high by the power supply to indicate that +5VDC and +3.3VDC output are above the under voltage thresholds of the power supply TTL. compatible signal out with 100ms to 500ms.
> OVER POWER PROTECTION: The power supply shall shut down when output power exceeds 130﹪to 160﹪ of full load and require a power on cycle be performed by the operate
> OVER VOLTAGE PROTECTION: Standard on +5.0V output, set at 6.25VDC ±0.75VDC.
> SHORT CIRCUIT PROTECTION: A short circuit placed between the DC Return and the output shall cause No damage and the power supply shall shutdown.
> EMI: FCC part 15, Subpart B, Class B, EN55022 CISPR22 Class B, CE Make, EN61000-3-3;1995, EN61000-4-2, -3, -4, -5, -6, -11
> AGAENCY APPROVALS: UL 1950 QQGQ2, UL 1950 QQGQ8, TUV Rheinland (EN60950, IEC950 mod), CB Certification
> MTBF OF POWER SUPPLY ELECTRONNIS: 100,000 hours at full load and 25℃ ambient temperature.
> LIFE EXPCTANCY OF FAN: 40,000 hours at 40℃
|
|